This specification covers seamless tube and ferrule stock of copper and various copper alloys up to 79 mm, inclusive, in diameter, for use in surface condensers, evaporators, and heat exchangers.
Formerly under the jurisdiction of Committee B05 on Copper and Copper Alloys, this specification was withdrawn in October 2004 and replaced by B 111/B 111M-04.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard's Document Summary page on the ASTM website.
Область применения1.1 This specification covers seamless tube and ferrule stock of copper and various copper alloys up to 79 mm, inclusive, in diameter, for use in surface condensers, evaporators, and heat exchangers. Tubes for this application are normally made from the following coppers or copper alloys:
Copper or Copper Alloy UNS No.3 | Previously Used Designation | Type of Metal |
C10100 | OFE | Oxygen-free electronic |
C10200 | OFA | Oxygen-free without residual de-oxidants |
C10300 | . . . | Oxygen-free, extra low phosphorus |
C10800 | . . . | Oxygen-free, low phosphorus |
C12000 | DLPA | Phosphorized, low residual phosphorus |
C12200 | DHPA | Phosphorized, high residual phos-phorus |
C14200 | DPAA | Phosphorized, arsenical |
C19200 | . . . | Phosphorized, 1 % iron |
C23000 | . . . | Red Brass |
C28000 | . . . | Muntz Metal |
C44300 | . . . | Admiralty Metals, B, C, and D |
C44400 | ||
C44500 | ||
C60800 | . . . | Aluminum Bronze |
C61300 | . . . | |
C61400 | . . . | Aluminum Bronze, D |
C68700 | . . . | Aluminum Brass, B |
C70400 | . . . | 95-5 Copper-Nickel |
C70600 | . . . | 90-10 Copper-Nickel |
C71000 | . . . | 80-20 Copper-Nickel |
C71500 | . . . | 70-30 Copper-Nickel |
C71640 | . . . | Copper-nickel-iron-manganese |
C72200 | . . . | . . . |
Note 1--This specification is the metric companion to Specification B111.
Note 2--Warning: Mercury is a definite health hazard in use and disposal. (See 12.1.)
1.2 The following safety hazards caveat pertains only to the test methods portion, Section 18, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.