ASTM C1162/C1162M-90(2015)
Standard Test Method for Loose Density of Asbestos (Withdrawn 2021)
2 стр.
Отменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.40 Products in fibre-reinforced cement / Изделия из цемента, армированного волокном
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Причина отменыThis test method covers the determination of the loose density of asbestos fiber for Groups 5 to 9, inclusive (as determined by Test Method D3639/D3639M).

Formerly under the jurisdiction of Committee C17 on Fiber-Reinforced Cement Products, this test method was withdrawn in May 2021. This standard is being withdrawn without replacement due to its limited use by industry.

Значение и использование

5.1 Loose density gives an indication of the degree of fiberization, harshness, and loftiness of asbestos fiber.

Область применения

1.1 This test method covers the determination of the loose density of asbestos fiber for Groups 5 to 9, inclusive (as determined by Test Method D3639/D3639M).2

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”3

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard warning, see 1.3.

Ключевые слова:
asbestos; bulk; bulk density; loose density;