(812) 309-78-59
(495) 223-46-76
ASTM C1182-09
Standard Test Method for Determining the Particle Size Distribution of Alumina by Centrifugal Photosedimentation
3 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
81.060.10 Raw materials / Сырье
Сборник (ASTM):
15.02 Glass; Ceramic Whitewares / Стекло, Фарфорофаянсовые керамические изделия
Тематика:
Glass, Ceramics
Описание
Значение и использование

Manufacturers and users of alumina powders will find this test method useful to determine the particle size distribution of these materials for product specification, quality control, and research and development testing.

Область применения

1.1 This test method covers the determination of the particle size distribution of alumina in the range from 0.1 to 20 μm having a median particle diameter from 0.5 to 5.0 μm.

1.2 The procedure described in this test method may be successfully applied to other ceramic powders in this general size range. It is the responsibility of the user to determine the applicability of this test method to other material.

1.3 The values stated in SI units are to regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
alumina; particle size distribution; photosedimentation; Alumina powder--particle size distribution; Centrifugal sedimentation; Particle analysis--alumina/quartz/silica; Photosedimentation