(812) 309-78-59
(495) 223-46-76
ASTM C1249-18
Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications
13 стр.
Заменен
Электронный (pdf)Печатное издание
118.56 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
81.040.20 Glass in building / Стекло для строительства зданий
Сборник (ASTM):
04.07 Building Seals and Sealants; Fire Standards; Dimension Stone / Герметики и герметизация швов строительных конструкций; Стандарты по пожаробезопасности; Изделия из природного камня. Строительные изделия из природного камня
Тематика:
Buildings
Описание
Значение и использование

4.1 It should be realized that the design of an IG unit edge seal for use in SSG systems is a collaborative effort of at least the IG unit fabricator, sealant manufacturer, and design professional, among others.

4.2 This guide provides information on silicone sealants that are used for the secondary seal of IG units that are glazed into SSG systems.

4.3 Information is also provided on the other major components of the IG unit edge seal, compatibility of components, durability, and quality assurance (QA).

Область применения

1.1 This guide covers design and fabrication considerations for the edge seal of conventionally sealed insulating glass units, herein referred to as IG units. The IG units described are used in structural silicone sealant glazing systems, herein referred to as SSG systems. SSG systems typically are either two or four sided, glazed with a structural sealant. Other conditions such as one, three, five, six sided may be used.

1.2 This guides does not cover the IG units of other than conventional edge seal design (Fig. 1); however, the information contained herein may be of benefit to the designers of such IG units.

FIG. 1 Sealed IG Edge Seal: Basic Components

 Sealed IG Edge Seal: Basic Components Sealed IG Edge Seal: Basic Components

1.3 In an SSG system, IG units are retained to a metal framing system by a structural seal (Fig. 2). The size and shape of that seal, as well as numerous other SSG system design considerations, are not addressed in this guide.

FIG. 2 Typical A-Side SSG System Mullion: Horizontal Section (Vertical Joint)

 Typical A-Side SSG System Mullion: Horizontal Section
 (Vertical Joint) Typical A-Side SSG System Mullion: Horizontal Section
 (Vertical Joint)

1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 The committee with jurisdiction for this standard is not aware of any comparable standard guides published by other organizations.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Ключевые слова:
adhesive failure; cohesive failure; edge seal; insulating glass; secondary seal; structural sealant; structural sealant glazing ;