(812) 309-78-59
(495) 223-46-76
ASTM C1459-00
Standard Specification for Performance of Non-Asbestos Fiber-Reinforced Cement Shake, Shingle, and Slate Roofing Systems
4 стр.
Заменен
Электронный (pdf)Печатное издание
81.12 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.15 Mineral. Including earth, sands, clay, slates, stones, etc. / Минеральные материалы и изделия. Включая землю, песок, глину, шифер, камень, кирпич и т.д.
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Область применения

1.1 This specification covers the performance of non-asbestos, fiber-reinforced cement shake, shingle, and slate roofing systems that are of uniform or nonuniform thickness and texture.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.2 The values stated in inch-pound units are regarded as the standard. The values given in parentheses (SI units) are given for information only.

1.3 This specification does not include details of product installation and workmanship. The manufacturer's installation instructions shall be referred to for details such as slope, interlayment, underlayment, sheathing requirements, exposure, fasteners, and repair or replacement instructions.

1.4 This specification does not address requirements for individual shake, shingle, and slate products, which are covered in Specification C 1225.

1.5 The tests contained in this specification are intended as qualification tests for a roofing system. Changes in product formulation, design, or manufacturing process beyond the ranges allowed in the manufacturer's quality control specifications, shall require subsequent system retesting or written concurrence by an independent testing agency that the changes in formulation, design, or manufacturing process will not be detrimental to system performance.

Ключевые слова:
fiber-cement; fiber-reinforced cement; fire-resistant; heat/rain/test; installed strength; installed weight; qualification testing; restricted frame; roofing; shake; shingle; slate; tile; wet/dry cycling