(812) 309-78-59
(495) 223-46-76
ASTM C24-09
Standard Test Method for Pyrometric Cone Equivalent (PCE) of Fireclay and High Alumina Refractory Materials
Стандартный метод испытания для определения огнеупорности по пирометрическому конусу (РСЕ) шамотных и высокоглинозёмистых огнеупорных материалов
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
81.080 Refractories. Including ceramic refractories / Огнеупоры. Включая огнеупоры из керамики
Сборник (ASTM):
15.01 Refractories, Activated Carbon; Advanced Ceramics / Огнеупорные материалы; Активированный уголь, Высококачественная керамика
Тематика:
Refractories
Описание
Значение и использование

The deformation and end point of a cone corresponds to a certain heat-work condition due to the effects of time, temperature, and atmosphere.

The precision of this test method is subject to many variables that are difficult to control. Therefore, an experienced operator may be necessary where PCE values are being utilized for specification purposes.

PCE values are used to classify fireclay and high alumina refractories.

This is an effective method of identifying fireclay variations, mining control, and developing raw material specifications.

Although not recommended, this test method is sometimes applied to materials other than fireclay and high alumina. Such practice should be limited to in-house laboratories and never be used for specification purposes.

Область применения

1.1 This test method covers the determination of the Pyrometric Cone Equivalent (PCE) of fire clay, fireclay brick, high alumina brick, and silica fire clay refractory mortar by comparison of test cones with standard pyrometric cones under the conditions prescribed in this test method.

1.2 UnitsThe values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.2.1 ExceptionsCertain weights are in SI units with inch-pound in parenthesis. Also, certain figures have SI units without parenthesis. These SI units are to be regarded as standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
PCE; pyrometric cone; pyrometric cone equivalent; refractories; Pyrometric cone equivalent (PCE); Refractories (alumina); Refractories (brick and shapes)--fireclay; Refractories (bricks and shapes); Refractories (fireclay); Refractories (silica)