(812) 309-78-59
(495) 223-46-76
ASTM C265-08
Standard Test Method for Water-Extractable Sulfate in Hydrated Hydraulic Cement Mortar (Withdrawn 2017)
3 стр.
Отменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.10 Cement. Gypsum. Lime. Mortar / Цемент. Гипс. Известь. Строительный раствор
Сборник (ASTM):
04.01 Cement; Lime; Gypsum / Цемент, Известь, Гипс
Тематика:
Cement & Concrete
Описание
Причина отменыThis test method covers the measurement of water-extractable SO3 in hardened hydraulic cement mortar. This measurement is assumed to represent unreacted, available sulfate remaining in the mortar.

Formerly under the jurisdiction of ASTM Committee C01 on Cement, this test method was withdrawn in January 2017 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

Excess soluble sulfate ions in hardened cement can result in reduced durability. This test method is intended to show whether calcium sulfate has been used in cement in such amount to leave excess soluble sulfate in hardened mortar. The test method is used to establish compliance in Specification C 595 for those cements in which optimized SO3 exceeds the table limit. This test method also can provide useful information on other hydraulic cements, such as those specified in Specifications C 150 and C 1157.

When this test method is used in conjunction with Test Method C 563, use the appropriate age of test specimens (24 h, 3 days, or 7 days) to coincide with the age of specimens used in Test Method C 563.

Область применения

1.1 This test method covers the measurement of water-extractable SO3 in hardened hydraulic cement mortar. This measurement is assumed to represent unreacted, available sulfate remaining in the mortar.

1.1.1 WarningFresh hydraulic cementious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 Values in SI units were obtained by measurement in SI units or by appropriate conversion using the Rules for Conversion and Rounding given in IEEE/ASTM SI-10 Standard of measurements made in other units.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
hydraulic cement; optimum sulfate content; sulfate; sulfate content; Calcium sulfate (CaSO4); Cement mortars; Hydraulic cement concrete; Sulfur trioxide (SO3); Water-extractable matter/processing