(812) 309-78-59
(495) 223-46-76
ASTM C386-93(2012)
Standard Practice for Use of Chemical-Resistant Sulfur Mortar (Withdrawn 2021)
3 стр.
Отменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.10 Cement. Gypsum. Lime. Mortar / Цемент. Гипс. Известь. Строительный раствор
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Причина отменыThis practice provides detailed information on the handling, installation, and proper use of chemical-resistant sulfur mortar such as those covered in Specification C287.

Formerly under the jurisdiction of Committee C03 on Chemical-Resistant Nonmetallic Materials, this practice was withdrawn in January 2021 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Реферат

This practice covers detailed information on the handling, installation, and proper use of chemical-resistant sulfur mortar. The sulfur mortar shall be stored in unopened containers and in a clean, dry place to prevent contamination of the product. Sulfur mortar must be heated and molten in order to be used. Adequate ventilation should be provided whether sulfur mortars are used. All surfaces which molten sulfur mortar will contact must be dry to prevent splattering. Horizontal joints may be formed by resting each brick or tile on three spacers which are placed in a triangular pattern. The floor shall be given a skim coat of sulfur mortar prior to installing brick or tile. The chemical resistance of sulfur mortars shall be determined.

Область применения

1.1 This practice provides detailed information on the handling, installation, and proper use of chemical-resistant sulfur mortar such as those covered in Specification C287.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety precautions, see Section 5.

Ключевые слова:
brick; chemical-resistant; sulfur mortar; tile