(812) 309-78-59
(495) 223-46-76
ASTM C700-09
Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
23.040.50 Pipes and fittings of other materials / Трубы и фитинги из других материалов
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Реферат

This specification covers extra strength and standard strength vitrified clay pipe and fittings to be used for the conveyance of sewage, industrial wastes, and storm water; and extra strength perforated and standard strength perforated vitrified clay pipe to be used for underdrainage, filter fields, leaching fields, and similar subdrainage installations. Vitrified clay pipe shall be manufactured from fire clay, shale, surface clay, or a combination of these materials that, when formed into pipe and fired to suitable temperatures. Pipe shall meet the bearing strength requirements prescribed. The manufacturer shall at his option, apply either a hydrostatic pressure test or an absorption test to all of the test specimens in each size and run of the pipe. The absorption of vitrified clay pipe shall not exceed 8%. The acid resistance test is used to determine the resistance of pipe to the action of acids encountered in sanitary sewers.

Область применения

1.1 This specification establishes the criteria for acceptance, prior to installation, of extra strength and standard strength vitrified clay pipe and fittings to be used for the conveyance of sewage, industrial wastes, and storm water; and extra strength perforated and standard strength perforated vitrified clay pipe to be used for underdrainage, filter fields, leaching fields, and similar subdrainage installations.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Note 1—Attention is called to Specification C425, Test Method C828, Test Method C1091, Test Methods C301, and Terminology C896.

1.3 The following precautionary caveat pertains only to the Test Method portion, 5.2-5.2.3.2 of this standard: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
absorption test; bearing strength; bell; chemical resistance; clay; corrosion resistance; drains; fittings; leachate; leaching fields; perforated pipe; pipe; plain end; sewers; spigot; vitrified; Glazing compounds/applications--specifications; Hydrostatic heads; Hydrostatic testing; Imperviousness; Leachate drainage; Nonpressure piping--specifications; Perforated clay; Permeability; Pressure testing--pipes; Acceptance criteria/testing; Acceptance criteria/testing--clay pipe/fittings; Bearing strength; Bell/spigot/plain end; Chemical-resistant materials/products; Clay materials/applications--specifications; Clay pipe/piping systems--specifications; Culvert pipe (vitrified clay); Proof test; Storm sewer/drainage pipe (clay); Straightness; Strength--construction materials/applications; Transmission pipe--specifications; Trenches; Vitrified clay pipe/fittings