ASTM D4597-03(2009)e1
Standard Practice for Sampling Workplace Atmospheres to Collect Gases or Vapors with Solid Sorbent Diffusive Samplers
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.100 Occupational safety. Industrial hygiene / Безопасность профессиональной деятельности. Промышленная гигиена13.040.30 Workplace atmospheres / Атмосфера рабочей зоны
Сборник (ASTM):
11.07 Air Quality / Атмосферный анализ
Тематика:
Atmospheric Analysis
Описание
Значение и использование

Regulations such as those promulgated by the U.S. Occupational Safety and Health Administration in 29 CFR 1910.1000 designate that certain hazardous gases and vapors must not be present in the workplace air at concentrations above specific values.

This practice, when used in conjunction with an analytical technique, such as that given for organic compounds in Practice D3687, may provide a means for the determination of time-weighted airborne concentrations of many of the hazardous gases and vapors in applicable regulations (for example, 29CFR 1919.1000,), as well as others.

The manufacturer's literature should be consulted for the appropriate list of chemicals which may be sampled by a particular device.

Область применения

1.1 This practice covers the sampling of workplace atmospheres for the presence of certain gases or vapors by means of diffusion across a specified quiescent region and subsequent sorption on a solid sorbent (1).

1.2 A list of organic compounds which are applicable to solid sorbent sampling where the sorbent is contained in a bed through which air is passed is given in Annex A1 of Practice D3686. Diffusive samplers may be applicable to a similar range of compounds but this must be confirmed by reference to the individual sampler manufacturers' literature.

1.3 The valid use of diffusive samplers depends on the existence of actual laboratory or field validation, or both. Guidance on validation can be obtained from published protocols (2-6). This practice is not designed to cover the verification, validation, or specific test procedures used to assess the accuracy or precision of diffusive samplers.

1.4 The values stated in SI units shall be regarded as the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
air monitoring; diffusive samplers; organic gases; organic vapors; sampling and analysis; workplace atmospheres; Activated charcoal; Air monitoring; Calibration--air/atmospheric analysis instruments; Contamination--atmospheric; Diffusional sampling; Diffusive samplers; Ethylene oxide (ETO)--workplace; Formaldehyde; Gases (atmospheric); Sulfur dioxide (SO2)--atmospheric; Gas phase diffusion; Hydrazine; Hydrogen sulfide--atmospheric analysis; Vapor phase analysis/processing--atmospheric; Methanol (methyl alcohol); Nitrogen dioxide (NO2) content; Organic compounds--atmospheric; Workplace air/atmospheres; Phenolic compounds; Sampling air/atmospheric materials/applications; Solid sorbent diffusional samplers