ASTM D4637-08
Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
Сборник (ASTM):
04.04 Roofing and Waterproofing / Кровельные покрытия и Гидроизоляционные материалы
Тематика:
Roofing
Описание
Реферат

This specification covers flexible sheet made from ethylene-propylene-diene terpolymer (EPDM) intended for use in single-ply roofing membranes exposed to the weather. The rubber sheet may be non-reinforced (Type I), fabric or scrim internally reinforced (Type II), or fabric-backed (Type III) vulcanized. In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are beyond the scope of this specification. The physical requirements for which flexible sheets shall be tested on and accordingly conform to are as follows: sheet-overall and coating over scrim or fabric thicknesses; breaking strength; tensile strength and set; dynamic and static puncture resistance; ultimate elongation and elongation at fabric break; tear resistance and strength; brittleness point; ozone resistance; behavior upon heat aging; linear dimensional change; water absorption; factory seam strength; weather resistance; and fabric adhesion.

Область применения

1.1 This specification covers flexible sheet made from ethylene-propylene-diene terpolymer (EPDM) intended for use in single-ply roofing membranes exposed to the weather. The tests and property limits used to characterize the sheet are values to ensure minimum quality for the intended use. The sheet may be non-reinforced, fabric- or scrim-reinforced, or fabric-backed vulcanized rubber sheet.

1.2 In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are factors that must be considered but are beyond the scope of this specification.

1.3 The values stated in SI units are to be regarded as the standard. The values stated in parentheses are for information only.

1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
EPDM; roofing; rubber sheet; single-ply membrane; vulcanized rubber; EPM/EPDM roofing materials/applications; Fabric roofing applications--specifications; Polychloroprene--specifications; Roofing materials/applications--specifications; Roofing membranes--specifications; Rubber roofing materials--specifications; Single-ply roof membrane; Unreinforced vulcanized rubber sheet; Vulcanized rubbers