(812) 309-78-59
(495) 223-46-76
ASTM D4829-08a
Standard Test Method for Expansion Index of Soils
5 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
93.020 Earthworks. Including geotechnics / Земляные работы. Выемка грунта. Сооружение фундаментов. Подземные работы. Включая геотехнику
Сборник (ASTM):
04.08 Soil and Rock (I): D420 – D5876 / Грунт и Горные породы (I): D420 – D5876
Тематика:
Geotechnical Engineering
Описание
Значение и использование

The expansion index, EI, provides an indication of swelling potential of a compacted soil.

The EI test is not used to duplicate any particular field conditions such as soil density, water content, loading, in-place soil structure, or soil water chemistry. However, consistent test conditions are used in preparation of compacted specimens such that direct correlation of data can be made between organizations.

Note 1—Qualitative classification of potential expansion in a soil based on EI is provided in Table 1.

Note 2—Notwithstanding the statements on precision and bias contained in this test method: The precision of this test method is dependent on the competence of the personnel performing it and the suitability of the equipment and facilities used. Agencies which meet the criteria of Practice D 3740 are generally considered capable of competent testing. Users of this test method are cautioned that compliance with Practice D 3740 does not ensure reliable testing. Reliable testing depends on several factors; Practice D 3740 provides a means of evaluating some of those factors.

TABLE 1 Classification of Potential Expansion of Soils Using EI

Expansion Index, EIPotential
Expansion
020Very Low
2150Low
5190Medium
91130High
>130Very High
Область применения

1.1 This test method allows for determination of expansion potential of compacted soils when inundated with distilled water.

1.2 This test method provides a simple yet sensitive method for determination of expansion potential of compacted soils for practical engineering applications using an index parameter.

1.3 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are approximate.

1.4 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026.

1.4.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
clays; expansive soils; index tests; laboratory tests; soil moisture; swelling soils; Compaction measurement--soils; Dimensional change; Distilled water; Expansion index (EI); Saturation; Soil; Specimen preparation (for testing)--soil; Thickness; Water content--soil