5.1 The penetration test is used as a measure of consistency. Higher values of penetration indicate softer consistency.
1.1 This test method covers determination of the penetration of semi-solid and solid bituminous materials.
1.2 The needles, containers and other conditions described in this test method provide for the determinations of penetrations up to 500.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.