(812) 309-78-59
(495) 223-46-76
ASTM D5086-95
Standard Test Method for Determination of Calcium, Magnesium, Potassium, and Sodium in Atmospheric Wet Deposition by Flame Atomic Absorption Spectrophotometry
8 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
93.60 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
07.060 Geology. Meteorology. Hydrology / Геология. Метеорология. Гидрология71.040.40 Chemical. Including analysis of gases and surface chemical analysis / Химический анализ. Включая анализ газов
Сборник (ASTM):
11.07 Air Quality / Атмосферный анализ
Тематика:
Atmospheric Analysis
Описание
Область применения

1.1 This test method is applicable to the determination of calcium, magnesium, potassium, and sodium in atmospheric wet deposition (rain, snow, sleet, and hail) by flame atomic absorption spectrophotometry (FAAS). (1)

1.2 The concentration ranges are listed below. The range tested was confirmed using the interlaboratory collaborative test (see for a statistical summary of the collaborative test).

MDL (mg/L)(2)Range of Method (mg/L)Range Tested (mg/L)
Calcium 0.0090.03-3.000.168-2.939
Magnesium0.0030.01-1.00 0.039-0.682
Potassium0.0030.01-1.00 0.029-0.499
Sodium 0.0030.01-2.000.105-1.84

1.3 The method detection limit (MDL) is based on single operator precision (2) and may be higher or lower for other operators and laboratories. Many workers have found that this test method is reliable at lower levels than were tested, but the precision and bias data presented are insufficient to justify their use at lower levels.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 8.3, 8.7, 12.1.8, and Section 9.

Ключевые слова:
atmospheric wet deposition; atomic absorption; calcium; magnesium; potassium; precipitation; sodium