(812) 309-78-59
(495) 223-46-76
ASTM D5269-96(2002)
Standard Test Method for Determining Transmissivity of Nonleaky Confined Aquifers by the Theis Recovery Method
5 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
93.160 Hydraulic construction / Сооружение гидротехнических объектов
Сборник (ASTM):
04.08 Soil and Rock (I): D420 – D5876 / Грунт и Горные породы (I): D420 – D5876
Тематика:
Geotechnical Engineering
Описание
Область применения

1.1 This test method covers an analytical procedure for determining the transmissivity of a confined aquifer. This test method is used to analyze data from the recovery of water levels following pumping or injection of water to or from a control well at a constant rate.

1.2 The analytical procedure given in this test method is used in conjunction with the field procedure in Test Method D 4050.

1.3 LimitationsThe valid use of the Theis recovery method is limited to determination of transmissivities for aquifers in hydrogeologic settings with reasonable correspondence to the assumptions of the Theis theory (see 5.1).

1.4 The values stated in SI units are to be regarded as standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
aquifers; aquifer tests; confined aquifers; control wells; ground water; hydraulic properties; observation wells; step tests; transmissivity; unconfined aquifers