Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)
Стандартный метод испытания для определения температуры потери текучести нефтепродуктов (Метод автоматического наклона)
5 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
75.080 Petroleum products in general / Нефтяные продукты в целом
Сборник (ASTM):
05.02 Petroleum Products, Liquid Fuels, and Lubricants (II): D3711–D6122 / Нефтепродукты, жидкое топливо и смазочные материалы (II): D3711–D6122
Тематика:
Petroleum
Описание
Значение и использование

The pour point of a petroleum product is an index of the lowest temperature of its utility for certain applications. Flow characteristics, like pour point, can be critical for the correct operation of lubricating oil systems, fuel systems, and pipeline operations.

Petroleum blending operations require precise measurement of the pour point.

This test method can determine the pour point of the test specimen with a resolution of 1.0°C.

Test results from this test method can be determined at either 1 or 3°C intervals.

This test method yields a pour point in a format similar to Test Method D 97/IP15 when the 3°C interval results are reported.

Note 3—Since some users may wish to report their results in a format similar to Test Method D 97 (in 3°C intervals) the precisions were derived for the temperatures rounded to the 3°C intervals. For statements on bias relative to Test Method D 97, see 13.3.

This test method has better repeatability and reproducibility relative to Test Method D 97/IP15 as measured in the 1998 interlaboratory test program. (See Section 13.)

Область применения

1.1 This test method covers the determination of pour point of petroleum products by an automatic instrument that tilts the test jar during cooling and detects movement of the surface of the test specimen with an optical device.

1.2 This test method is designed to cover the range of temperatures from 57 to +51°C; however, the range of temperatures included in the 1992 interlaboratory test program only covered the temperature range from 39 to +6°C, and the range of temperatures included in the 1998 interlaboratory test program was 51 to 11°C. (See Section 13.)

1.3 Test results from this test method can be determined at 1 or 3°C intervals.

1.4 This test method is not intended for use with crude oils.

Note 1—The applicability of this test method on residual fuel samples has not been verified. For further information on applicability, refer to 13.4.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
D97 equivalent; petroleum products; pour point; tilt method; Automated procedures--petroleum products analysis; Fuel oils; Fuel systems; Instrumental measurement--petroleum products; Lubricating oils; Petroleum products; Pipeline operations; Pour point--petroleum products