ASTM D6126/D6126M-11(2015)
Standard Specification for HFC-23 (Trifluoromethane, CHF3)
3 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
71.080.20 Halogenated hydrocarbons / Галогензамещенные углеводороды13.220.10 Fire-fighting. Including equipment and vehicles / Пожаротушение. Включая оборудование и транспорт
Сборник (ASTM):
15.05 Engine Coolants and Related Fluids; Halogenated Organic Solvents and Fire Extinguishing Agents / Охлаждающие жидкости двигателя, Галогенизированные органические растворители и Огнетушащие вещества; Промышленные и специализированные химикаты
Тематика:
Industrial Hygiene & Safety
Описание
Реферат

This specification covers the test methods and requirements for HFC-23 (trifluoromethane, CHF3) as a fire fighting medium. This specification, however, does not address the fire fighting equipment or hardware that employs HFC-23 or the conditions of employing such equipment (for example, handshields, fixed installations, etc.). It also does not address the storage or transportation of HFC-23. When analyzed by appropriate test methods, sampled specimens shall conform to requirements as to purity, acidity, water content, nonvolatile residue, and suspended matter or sediment.

Область применения

1.1 This specification covers the requirements for HFC-23 as a fire fighting medium.

1.2 This specification does not address the fire fighting equipment or hardware that employs HFC-23 or the conditions of employing such equipment (for example: handshields, fixed installations, etc.).

1.3 This specification does not address the storage or transportation of HFC-23 Storage handling, and transportation issues are addressed in Practice D6127.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5 The following safety hazards caveat pertains to the test methods portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
CHF3; FE-13™; fire fighting; fire fighting agent; fire protection; fire suppressant; HFC-23; hydrofluorocarbon; trifluoromethane;