(812) 309-78-59
(495) 223-46-76
ASTM D6564/D6564M-17
Standard Guide for Field Filtration of Groundwater Samples
6 стр.
Заменен
Электронный (pdf)Печатное издание
117.00 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.060.10 Water of natural resources / Вода естественных источников
Сборник (ASTM):
04.09 Soil and Rock (II): D5878 – latest / Грунт и Горные породы (II): с D5878 и далее
Тематика:
Geotechnical Engineering
Описание
Значение и использование

4.1 A correctly designed, installed and developed groundwater monitoring well, constructed in accordance with Practice D5092, should facilitate collection of samples of groundwater that can be analyzed to determine both the physical and chemical properties of that sample. Samples collected from these wells that require analysis for dissolved constituents should be filtered in the field prior to chemical preservation and shipment to the laboratory for analysis.

Область применения

1.1 This guide covers methods for field filtration of groundwater samples collected from groundwater monitoring wells, excluding samples that contain non-aqueous phase liquids (either Dense Non-Aqueous Phase Liquids (DNAPLs) or Light Non-Aqueous Phase Liquids (LNAPLs)). Methods of field filtration described herein could also be applied to samples collected from wells used for other purposes. Laboratory filtration methods are not described in this guide.

1.2 This guide provides procedures available for field filtration of groundwater samples. The need for sample filtration for specific analytes should be defined prior to the sampling event and documented in the site-specific sampling and analysis plan in accordance with Guide D5903. The decision should be made on a parameter-specific basis with consideration of the data quality objectives of the sampling program, any applicable regulatory agency guidelines, and analytical method requirements.

1.3 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This guide cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This guide is not intended to represent or replace the standard of care by which the adequacy of a given professional service to be judged, nor should this guide be applied without consideration of the many unique aspects of a project. The word “Standard” in the title of this guide means only that the guide has been approved through the ASTM consensus process.

1.4 Units—The values stated in either SI Units or inch-pound units given in brackets are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Ключевые слова:
capsule filters; disk filters; dissolved constituents; filter pore size; groundwater samples; negative pressure filtration; positive pressure filtration; pressure filtration; preconditioning filters; sample filtration;