(812) 309-78-59
(495) 223-46-76
ASTM D8049-16
Standard Test Method for Determining Concentration, Count, and Size Distribution of Solid Particles and Water in Light and Middle Distillate Fuels by Direct Imaging Particle Analyzer
6 стр.
Заменен
Электронный (pdf)Печатное издание
93.60 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
75.160.20 Liquid. Including gasoline, diesel, kerosene, etc. / Жидкое топливо
Сборник (ASTM):
05.05 Petroleum Products, Liquid Fuels, and Lubricants (V): D7756–latest; Combustion Characteristics; Manufactured Carbon and Graphite Products / Нефтепродукты, жидкое топливо и смазочные материалы (V): с D7756 и далее; Характеристики возгорания; Искусственный углерод и изделия из графита
Тематика:
Petroleum
Описание
Значение и использование

5.1 This test method is intended for use in the laboratory or in the field for evaluating the cleanliness of fuels identified in the scope.

5.2 Detection of particles and water can indicate degradation of the fuel condition. Particles, whether inorganic or organic, can cause fouling of fuel filters and damage pumps, injectors, and pistons. Knowledge of particle size in relation to metallurgy can provide vital information, especially if the hardness of the solid particles are known from other sources.

Note 3: The method includes the detection of water, solids, and air bubbles. The air bubbles are screened out of the data prior to analysis of results, based on shape and transparency, and are not reported in the results.

Область применения

1.1 This test method uses a direct imaging particle analyzer (DIPA) to count and measure the size and shape of dispersed solid particles and water droplets in light and middle distillate fuels in the overall range from 4 μm to 100 μm and in size bands of 4 μm, 6 μm, and 14 μm.

Note 1: Particle size data from 0.7 μm through 300 μm is available for use or reporting if deemed helpful.

Note 2: Shape is used to classify particles, droplets, and bubbles and is not a reporting requirement.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
middle distillate fuels; particle analyzer; particle counting; particle size; particulate contamination;