This test method describes a procedure for the estimation of the log of the octanol/water partition coefficient (log
Formerly under the jurisdiction of Committee E47 on Biological Effects and Environmental Fate, this test method was withdrawn in March 2013. This standard is being withdrawn without replacement due to its limited use by industry.
Область применения1.1 This test method describes a procedure for the estimation of the log of the octanol/water partition coefficient (log K
1.2 This test method uses an empirically derived equation to relate the octanol/water partition coefficient to an experimentally determined retention time on a liquid chromatographic column.
1.3 This test method has been designed to estimate log K
1.4 This test method requires some knowledge of the detector response to the chemical being tested.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish safety and health practices and determine the applicability of regulatory limitations prior to use.