(812) 309-78-59
(495) 223-46-76
ASTM E1235-08
Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft
13 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
107.64 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
49.140 Space. Including space data and information transfer systems, and ground support equipment for launch site operations / Космические системы и операции. Включая космические системы передачи данных и информации и наземное вспомогательное оборудование для обеспечения выполнения операций на стартовой позиции49.025.01 Materials for aerospace construction in general / Материалы для авиационно-космических конструкций в целом
Сборник (ASTM):
15.03 Space Simulation; Aerospace and Aircraft; Composite Materials / Космическое моделирование; Аэрокосмическая и авиационная промышленности; Композиционные материалы
Тематика:
Aerospace Materials
Описание
Значение и использование

The NVR determined by this test method is that amount that can reasonably be expected to exist on hardware exposed in environmentally controlled areas.

The evaporation of the solvent at or near room temperature is to quantify the NVR that exists at room temperature.

Numerous other methods are being used to determine NVR. This test method is not intended to replace methods used for other applications.

Область применения

1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft.

1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

Ключевые слова:
gravimetric determination; nonvolatile residue; Acid decomposition; Aerospace applications; Contamination--aerospace materials/applications; Environmental control/fate--aerospace applications; Gravimetric determination; Mass per unit area; Nonvolatile residue (NVR); Residue