ASTM E1375-90(2002)
Standard Test Method for Measuring the Interzone Attenuation of Furniture Panels Used as Acoustical Barriers (Withdrawn 2005)
6 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.120.20 Acoustics in building. Sound insulation / Акустика в зданиях. Звукоизоляция
Сборник (ASTM):
04.06 Thermal Insulation; Building and Environmental Acoustics / Теплоизоляция; Внутренняя звукоизоляция зданий и звукоизоляция от внешней среды
Тематика:
Buildings
Описание
Причина отмены

This test method covers the measurement of the interzone attenuation of furniture panels used as acoustical barriers in open-plan spaces to provide speech privacy or sound isolation between working positions.

This test method was part of a suite of standard test methods for measuring the Interzone Attenuation of various open office components. Test Method E 1111 in its latest revision now covers the testing of the components previously covered in Test Method E 1375.

Formerly under the jurisdiction of ASTM Committee E33 on Environmental Acoustics, this test method was withdrawn in October 2005 and replaced with Test Method E 1111.

Область применения

1.1 This test method covers the measurement of the interzone attenuation of furniture panels used as acoustical barriers in open-plan spaces to provide speech privacy or sound isolation between working positions.

1.2 This test procedure was originally developed using the foot-pound system of units for prescribing measurement positions and distances. However, the use of SI units is preferred by ASTM. For this reason, dimensions are provided in SI units, with approximate foot-pound conversions indicated.

1.2.1 Unless otherwise qualified, all dimensions specified in this test method shall be understood to have a tolerance of ± 25 mm (± 1 in.), even though the indicated approximate conversions of the numerical dimensions given will not always be accurate to this extent. All measurements shall be made in SI units or the corresponding exact foot-pound units.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
acoustical barrier; acoustical component; architectural acoustics; component test; furniture panel; interzone attenuation; open office; open office component; open-plan space; speech privacy