19.100 Non-destructive. Including testing equipment: industrial apparatus for X-ray and gamma radiography, penetrant flaw detectors, etc. / Неразрушающие испытания. Включая испытательное оборудование: промышленная аппаратура для рентгеновской и гамма-радиографии, проникающие дефектоскопы и т.д.77.040.20 Non-destructive testing of metals / Неразрушающие испытания металлов
Сборник (ASTM):
03.03 Nondestructive Testing (I): C1331 – E2373 / Неразрушающий контроль (I): C1331 – E2373
Тематика:
Nondestructive Testing
Описание
Область применения

1.1 This practice establishes the minimum requirements for radiographic examination for metallic and nonmetallic materials.

1.2 ApplicabilityThe criteria for the radiographic examination in this practice are applicable to all types of metallic and nonmetallic materials. The requirements expressed in this practice are intended to control the quality of the radiographic images and are not intended to establish acceptance criteria for parts and materials.

1.3 Basis of ApplicationThere are areas in this practice that may require agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract.

1.3.1 DoD contracts.

1.3.2 Personnel qualification, .

1.3.3 Agency qualification, .

1.3.4 Digitizing techniques, .

1.3.5 Alternate image quality indicator (IQI) types, .

1.3.6 Examination sequence, .

1.3.7 Non-film techniques, .

1.3.8 Radiographic quality levels, .

1.3.9 Film density, .

1.3.10 IQI qualification exposure, .

1.3.11 Non-requirement for IQI, .

1.3.12 Examination coverage for welds, .

1.3.13 Electron beam welds, .

1.3.14 Geometric unsharpness, .

1.3.15 Responsibility for examination, .

1.3.16 Examination report, .

1.3.17 Retention of radiographs, .

1.3.18 Storage of radiographs, .

1.3.19 Reproduction of radiographs, and .

1.3.20 Acceptable parts, .

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
image quality indicator; nondestructive testing; penetrating radiation; radiographic; radiographic examination; radiography; radioscopy; X-ray