(812) 309-78-59
(495) 223-46-76
ASTM E1853-96
Guide for Measuring the Presence of Planar Organic Compounds Which Induce CYP1A, Using Reporter Gene Test Systems
6 стр.
Отменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
07.080 Biology. Including biotechnology / Биология. Ботаника. Зоология. Включая биотехнологии
Сборник (ASTM):
11.05 Environmental Assessment, Risk Management and Corrective Action / Оценка состояния окружающей среды, риск-менеджмент и корректирующие мероприятия
Тематика:
Environmental Toxicology
Описание
Область применения

1.1 This guide covers the recommended guidelines for perfoming a test for presence of organic compounds that bind to the Ah Receptor and induce the CYP1A locus on the vertebrate chromosome. Under appropriate test conditions, induction of CYP1A is evidence that cells have been exposed to one or more of these xenobiotic organic coimpounds, including dioxins, furans, coplanar PCBs, and several polycyclic aromatic hydrocarbons (PAHs). Detection of induction has been made simple and rapid by the stable integration of the firefly plasmid such that Ah-receptor binding results in the production of luciferase. Luciferase production is a function of both the potency of the compound(s) and the concentration. This type of Reporter Gene System (RGS) has shown concentration-response relationships using 2,3,7,8-TCDD, 5 coplanar PCBs, and several polycyclic aromatic hydrocarbons (PAHs) (1,2). This guide describes test conditions under which solvent extracts of environmental samples (water, tissue, soil, or sediments) may be tested for the presence of CYP1A-inducing organic compounds.

1.2 The test procedures presented in this guide have been published previously (1-3). These references shoud be consulted to obtain details regarding the construction and maintenance of the cell line, and the response of the cells to various organic substances.

1.3 All laboratory health and safety procedures should be followed. This includes the use of glasses, gloves, and other protective clothing, when handling the reagents. Information on toxicity, handling procedures and waste procedures should be reviewed prior to use of all chemicals.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
Ah-receptor; biomarker; carcinogenic; coplanar organic compound; CYP1A; induction; P450 1A; reporter gene system; toxic