4.1 This practice is intended to be used by parties involved in the testing of floors and roofs of structures either in the field or the laboratory. Tests are either proof tests or tests to failure, and are applicable to all construction materials. The practice is not intended for use in routine quality control testing of individual building elements or constructions.
1.1 This practice covers static load testing of floors and low slope roofs (roofs having a slope of less than 1 in 12) under actual or simulated service conditions, and is applicable to typical elements or sections of structures fabricated for test or to actual existing building components. This practice is intended for use in determining the strength and stiffness of elements or sections of floors and roofs of buildings under gravity loads, as well as in checking the design, materials, connections, and the quality of the fabrication of such building constructions.