(812) 309-78-59
(495) 223-46-76
ASTM E1993-98(2008)
Standard Specification for Bituminous Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs
2 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.50 Binders. Including geomembranes, asphalts for buildings, etc. / Связующие вещества. Уплотнители. Включая геомембраны, строительный асфальт и т.д.
Сборник (ASTM):
04.11 Building Constructions (I): E72-E2110 / Строительство зданий (I): E72-E2110
Тематика:
Buildings
Описание
Реферат

This specification covers the properties and tests for bituminous membrane water vapor retarders used in contact with soil or granular fill under concrete slabs. Tests may be conducted on both new materials and materials that have been conditioned or exposed to simulate service conditions. The water vapor retarders shall consist of asphaltic materials reinforced with multiple plies of suitable fabric, and shall meet the following property requirements when tested: water vapor permeance; tensile strength; puncture resistance; and thickness. When specifically required by the buyer for use in special conditions, the retarders shall additionally adhere to properties such as resistance to plastic flow and elevated temperatures, effect of low temperature on bending, resistance to deterioration from petroleum vehicle for soil poisons, and resistance to deterioration from exposure to ultraviolet light.

Область применения

1.1 This specification covers bituminous water vapor retarders for use in contact or granular fill under concrete slabs.

1.2 The specified tests are conducted on new materials and materials that have been conditioned or exposed to simulate potential service conditions.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
bituminous; concrete; concrete slab; floor; vapor retarder; water vapor; Bituminous water vapor retarders; Building materials/applications--specifications; Concrete construction materials/applications--specifications; Concrete slabs; Flooring/floor covering systems--specifications; Flooring/floor covering systems (concrete); Vapor barriers--specifications; Water vapor retarders--specifications