(812) 309-78-59
(495) 223-46-76
ASTM E2322-03(2015)
Standard Test Method for Conducting Transverse and Concentrated Load Tests on Panels used in Floor and Roof Construction
6 стр.
Заменен
Электронный (pdf)Печатное издание
106.08 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.060.30 Ceilings. Including screeds, ramps, etc. / Потолки. Полы. Лестницы. Включая маяки, пандусы и т.д.
Сборник (ASTM):
04.12 Building Constructions (II): E2112-latest; Sustainability; Asset Management; Technology and Underground Utilities / Строительство зданий (II): с E2112 и далее; Устойчивость; Система управления недвижимостью (системы эксплуатации зданий и сооружений); Технологии и Подземные коммуникации
Тематика:
Buildings
Описание
Значение и использование

4.1 Transverse Load—The procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.

4.2 Concentrated Load—This concentrated load test shall be used to evaluate surface indentation of structural framing members.

4.3 These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E455. Impact loading shall be evaluated under Test Methods E661 or E695.

Область применения

1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions:

 

 

Section

 

Test Specimens

5

 

Loading

6

 

Deformation Measurements

7

 

Report

8

 

Precision and Bias

9

 

 Testing Floors

 

 

Transverse Load

10

 

Concentrated Load

11

 

 Testing Roofs

 

 

Transverse Load

12

 

Concentrated Load

13

1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.

1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

1.4 This standard is not intended to cover concrete floor slabs.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
concentrated loads; deformation; floors; load duration; roofs; sheathing; strength tests; transverse loads;