(812) 309-78-59
(495) 223-46-76
ASTM E2543-08
Standard Specification for Portable Air Heaters Used at Personnel Decontamination Stations and Shelters
3 стр.
Заменен
Электронный (pdf)Печатное издание
81.12 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.200 Accident. Including emergency evacuations and emergency control systems / Борьба с несчастными случаями и катастрофами. Включая аварийную эвакуацию и системы аварийного управления97.100.01 Heating appliances in general / Нагревательные приборы в целом
Сборник (ASTM):
15.08 Security Systems and Equipment; Detention and Correctional Facilities; Homeland Security Applications; Driverless Automatic Guided Industrial Vehicles; Exoskeletons and Exosuits / Оборудование и системы безопасности; Исправительные заведения и тюрьмы; Системы национальной безопасности; Беспилотный автоматически управляемый промышленный транспорт; Экзоскелеты и экзокостюмы
Тематика:
Consumer Products
Описание
Значение и использованиеp>The use of these acceptance tests will insure that organizations buying portable heaters will be assured the heaters meet certain performance requirements.

Реферат

This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud and grime with no degradation of the unit's ability to perform its function. The preferred fuels for the heater section of the portable air heater are diesel fuel, gasoline, or bottled propane gas. Measurement of the air heater unit's air flow and input and output temperatures shall be performed.

Область применения

1.1 This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency.

Note 1—These heaters are not intended to be used for the decontamination for any other surface or material. Also, these heaters are intended to be portable and easy to use by first responders during a chemical, biological, radiological, nuclear, and explosive (CBRNE) event.

1.2 This specification contains a specification section and a test methods section so users need to refer to the section applicable to their needs when using this standard specification.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

Note 2—The U.S. first responder personnel using the equipment manufactured under this standard are not likely to be familiar with SI units so English units need to be included as part of the system documentation and shown on control panels for any equipment sold to U.S. organizations.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

10.1 These test methods shall be used to insure portable air heaters comply with the requirements of this specification.

Ключевые слова:
decontamination; shelter; warm air