ASTM E323-09
Standard Specification for Perforated-Plate Sieves for Testing Purposes
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
19.120 Particle. Including test sieves and porosimetry / Ситовый анализ. Просеивание. Включая контрольные сита и измерение пористости
Сборник (ASTM):
14.02 Particle and Spray Characterization; Forensic Sciences; Accreditation & Certification; Forensic Psychophysiology; Nanotechnology; Forensic Engineering / Характеристика гранул и аэрозолей; Судебные науки; Аккредитация и сертификация; Судебная психофизиология; Нанотехнологии; Судебная инженерия
Тематика:
Physical Measurement
Описание
Реферат

This specification covers perforated-plate sieves with either round or square apertures, normally mounted in a frame for use in precision testing in the classification of materials according to designated nominal particle size. The materials used in the manufacture of these sieves shall be steel, stainless steel, brass, bronze, or other rigid material. Each plate of specified sieve designation and aperture size shall conform to individually allocated dimensional requirements.

Область применения

1.1 This specification covers perforated plate with either round or square apertures, normally mounted in a frame for use as sieves in precision testing in the classification of materials according to designated nominal particle size. A method for checking the accuracy of perforated sieve plates is included as information in Appendix X1.

Note 1—The perforated-plate sieves covered by this specification are intended for general precision testing. Some industries may require more restricted specifications for sieves for special testing purposes.

Note 2—For other types of sieves see Specifications E11 and E161.

Note 3—Complete instructions and procedures on the use of test sieves are contained in ASTM STP 447, Manual on Test Sieving Methods. This manual also contains a list of all ASTM published standards on sieve analysis procedures for specific materials or industries.

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
opening; particle size; perforated plate sieves; precision testing; seive analysis; sieve perforated plate; test sieve; Brass; Bronze; Metals and metallic materials; Nonferrous metals/alloys--specifications; Particle analysis; Precision instrumentation; Sieves; Stainless steel--specifications; Steel