(812) 309-78-59
(495) 223-46-76
ASTM E652-91(2009)
Standard Test Method for Nonresidual Liquid Household Insecticides Against Flying Insects (Withdrawn 2018)
4 стр.
Отменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
71.100.99 Other products of the chemical industry / Продукты химической промышленности прочие
Сборник (ASTM):
11.08 Pesticides, Antimicrobials, and Alternative Control Agents; Hazardous Substances and Oil Spill Response / Пестициды, противомикробные препараты и альтернативные средства контроля; Влияние опасных веществ и разлива нефти
Тематика:
Environmental Toxicology
Описание
Причина отменыThis test method covers the determination of the relative efficiency of household and industrial-use, contact insecticides dissolved in base oils.

Formerly under the jurisdiction of Committee E35 on Pesticides, Antimicrobials, and Alternative Control Agents, this test method was withdrawn in January 2018 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

This test method provides a satisfactory means of determining the relative efficacy of spray formulations against house flies (Musca domestica, L).

Test data obtained by this test method may also be adequate to support label claims for the use of the product against mosquitoes, gnats, flying moths, wasps, and certain other small flying insects. This test method is not designed to measure the residual action of the spray formulation.

As a biological test, it is subject to the variations that accompany the reactions of living organisms. It should be employed under the supervision of personnel familiar with the biological testing of insecticides.

Область применения

1.1 This test method covers the determination of the relative efficiency of household and industrial-use, contact insecticides dissolved in base oils.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
Calibration--environmental analysis instrumentation; Efficacy; House fly rearing technique; Insecticides; Liquid chemicals--agricultural applications; Nonresidual liquid household insecticides