(812) 309-78-59
(495) 223-46-76
ASTM E90-09
Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
15 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
107.64 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.120.20 Acoustics in building. Sound insulation / Акустика в зданиях. Звукоизоляция
Сборник (ASTM):
04.06 Thermal Insulation; Building and Environmental Acoustics / Теплоизоляция; Внутренняя звукоизоляция зданий и звукоизоляция от внешней среды
Тематика:
Buildings
Описание
Значение и использование

Sound transmission loss as defined in Terminology C 634, refers to the response of specimens exposed to a diffuse incident sound field, and this is the test condition approached by this laboratory test method. The test results are therefore most directly relevant to the performance of similar specimens exposed to similar sound fields. They provide, however, a useful general measure of performance for the variety of sound fields to which a partition or element may typically be exposed.

In laboratories designed to satisfy the requirements of this test method, the intent is that only significant path for sound transmission between the rooms is through the test specimen. This is not generally the case in buildings where there are often many other paths for soundsflanking sound transmission. Consequently sound ratings obtained using this test method do not relate directly to sound isolation in buildings; they represent an upper limit to what would be measured in a field test.

This test method is not intended for field tests. Field tests shall be performed according to Test Method E 336.

Note 2—The comparable quantity measured using Test Method E 336 is called the apparent sound transmission loss because of the presence of flanking sound transmission.

Область применения

1.1 This test method covers the laboratory measurement of airborne sound transmission loss of building partitions such as walls of all kinds, operable partitions, floor-ceiling assemblies, doors, windows, roofs, panels, and other space-dividing elements.

1.2 Laboratories are designed so the test specimen constitutes the primary sound transmission path between the two test rooms and so approximately diffuse sound fields exist in the rooms.

1.3 Laboratory AccreditationThe requirements for accrediting a laboratory for performing this test method are given in Annex A4.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
airborne sound transmission loss; flanking transmission; sound transmission coefficient; sound transmission loss; transmission loss; Acoustical tests; Diffuse sound field test; Doors/door assemblies; Floor-ceiling assemblies; Impact sound transmission (building elements); Laboratory sound transmission testing; Partitions; Sound transmission--building materials/applications; Specimen preparation (for testing)--sound transmission studies; Walls; Windows/window assemblies