(812) 309-78-59
(495) 223-46-76
ASTM E936-98(2004)
Standard Practice for Roof System Assemblies Employing Steel Deck, Preformed Roof Insulation, and Bituminous Built-Up Roofing (Withdrawn 2012)
26 стр.
Отменен
Электронный (pdf)Печатное издание
138.84 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.50 Binders. Including geomembranes, asphalts for buildings, etc. / Связующие вещества. Уплотнители. Включая геомембраны, строительный асфальт и т.д.
Сборник (ASTM):
04.04 Roofing and Waterproofing / Кровельные покрытия и Гидроизоляционные материалы
Тематика:
Roofing
Описание
Причина отмены

This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies. For this purpose, the roof system always includes steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.

Formerly under the jurisdiction of Committee D08 on Roofing and Waterproofing, this practice was withdrawn in October 2012 because it no longer has validity within the roofing industry.

Реферат

This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies that always include steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.

Область применения

1.1 This practice covers the performance requirements for the design, components, construction, and service expectations of new roof system assemblies. For this purpose, the roof system always includes steel deck, preformed roof insulation, and bituminous built-up roofing, and their attachment. It may also include fire-resistive components, integral acoustical treatment, vapor retarder, adhesive or mechanical fastener attachment, and aggregates.

1.2 The objective is to provide realistic criteria for the overall performance of the roof assembly and its components because by necessity and custom, a roof assembly contains a variety of components and is subject to varied environmental conditions.

1.3 To assist in the successful implementation of the installation and service requirements of the roof system assembly, criteria are established to provide for compatibility of the various components.

1.4 Nothing in this practice is intended to exclude products or systems not covered by the documents referenced in Section 2.

1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.