(812) 309-78-59
(495) 223-46-76
ASTM F1534-10
Standard Test Method for Determining Changes in Fire-Test-Response Characteristics of Cushioning Materials After Water Leaching
4 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.220.50 Fire-resistance of building materials and elements / Огнестойкость строительных материалов и элементов
Сборник (ASTM):
15.08 Security Systems and Equipment; Detention and Correctional Facilities; Homeland Security Applications; Driverless Automatic Guided Industrial Vehicles; Exoskeletons and Exosuits / Оборудование и системы безопасности; Исправительные заведения и тюрьмы; Системы национальной безопасности; Беспилотный автоматически управляемый промышленный транспорт; Экзоскелеты и экзокостюмы
Тематика:
Buildings
Описание
Значение и использование

The fire performance of a material or product is affected by a combination of its fire-test-response characteristics. Two of the most commonly determined fire-test-response characteristics of cushioning materials are the surface flammability, in accordance with Test Method D3675, and the specific optical density of smoke, in accordance with Test Method E662.

Cushioning materials used in upholstery applications are potentially exposed to leaching of the active ingredients due to (1) water solubility of the treating agents or (2) exposure to high humidity.

In view of the importance that the fire performance of the cushioning materials used in upholstery applications remain constant throughout their intended service life, this test method provides a means to test for the potential change in two fire-test-response characteristics due to leaching.

Область применения

1.1 This fire-test-response test method covers a procedure for leaching cushioning materials with water and determining changes in two specific fire-test-response characteristics: (1) the surface flammability, in accordance with Test Method D3675, and (2) the specific optical density of smoke generated, in accordance with Test Method E662.

1.2 In view of the wide variation in potential service conditions, it is likely that results of this leaching test will not give a direct correlation with service performance for all applications. However, the test method yields comparative data on which to base judgments as to expected service of cushioning materials and is useful in research and development work.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 7.

1.6 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

Ключевые слова:
cushioning; fire; fire performance; fire-test-response characteristic; leaching; optical density; smoke obscuration; softened water; Cushioning materials; Fire testing--building materials; Fire-test response; Leachates/leaching; Optical density; Smoke obscuration; Softened water; Upholstery fabrics/materials/applications; Water leaching