(812) 309-78-59
(495) 223-46-76
ASTM F1671/F1671M-13
Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System
11 стр.
Заменен
Электронный (pdf)Печатное издание
112.32 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.340.10 Protective. Including flameproof clothing / Защитная одежда. Включая огнестойкую одежду, индивидуальные плавсредства (спасательные жилеты)11.140 Hospital. Including hospital beds, surgical tables, medical garments, medical gloves, containers for sharp disposal, etc. / Больничное оборудование. Включая больничные кровати, операционные столы, медицинскую одежду, медицинские перчатки, контейнеры для удаления отходов и т.д.
Сборник (ASTM):
11.03 Occupational Health and Safety; Protective Clothing / Безопасность и охрана труда; Защитная спецодежда
Тематика:
Industrial Hygiene & Safety
Описание
Значение и использование

5.1 This test method is based on Test Method F903 for measuring resistance of chemical protective clothing materials to penetration by liquids. This test method is normally used to evaluate specimens from individual finished items of protective clothing and individual samples of materials that are candidates for items of protective clothing.

5.1.1 Finished items of protective clothing include gloves, arm shields, aprons, gowns, coveralls, hoods, and boots.

5.1.2 The phrase “specimens from finished items” encompasses seamed and other discontinuous regions, as well as the usual continuous regions of protective clothing items.

5.2 It is known that body fluids penetrating protective clothing materials are likely to carry microbiological contaminants; however, visual detection methods are not sensitive enough to detect minute amounts of liquid containing microorganisms (1,2,3).8 This test method uses media containing Phi-X174 Bacteriophage. The visual detection technique of this test method is supplemented with a biologically based assay capable of detecting virus under the specified test conditions.

5.3 Test Method F1670, allows the screening of protective clothing materials for resistance to penetration with synthetic blood as a challenge liquid. Test Method F1670 uses the same penetration test cell and technique, but exposes material specimens to synthetic blood with visual detection of liquid penetration. Materials passing Test Method F1670 should then be tested against bacteriophage penetration using this test method to verify performance.

5.4 This test method has been specifically designed for measuring penetration of a surrogate microbe for Hepatitis (B and C) and the Human Immunodeficiency Viruses. The surrogate, Phi-X174 Bacteriophage, used in this test method is similar to HCV in size and shape but also serves as a surrogate for HBV and HIV. Inferences about protection from other pathogens must be assessed on a case-by-case basis.

5.5 Part of the protocol in Procedure A and B in Table 1, for exposing the protective clothing material specimens to the Phi-X174 Bacteriophage challenge suspension, involves pressurization of the penetration cell to 13.8 kPa [2 psig]. This hydrostatic pressure has been documented to discriminate between protective clothing material performance and correlate with visual penetration results that are obtained with a human factors validation (4). Some studies, however, suggest that mechanical pressures exceeding 345 kPa [50 psig] can occur during actual clinical use (5, 6). Therefore, it is important to understand that this test method does not simulate all the physical stresses and pressures that might be exerted on protective clothing materials during actual use.

TABLE 1 Specimen Exposure Procedures

Procedure

Pressure/Time Sequence and Retaining Screen Options

A

0 kPa [0 psig] for 5 min, followed by 13.8 kPa [2 psig] for 1 min, followed by 0 kPa [0 psig] for 54 min.

 

A retaining screen is not used to support the specimen.

B

0 kPa [0 psig] for 5 min, followed by 13.8 kPa [2 psig] for 1 min, followed by 0 kPa [0 psig] for 54 min.

 

A retaining screen is used to support the specimen. The type must be specified.


5.6 Medical protective clothing materials are intended to be a barrier to blood, body fluids, and other potentially infectious materials. Many factors can effect the wetting and penetration characteristics of body fluids, such as: surface tension; viscosity; and polarity of the fluids, as well as the structure and relative hydrophilicity or hydrophobicity of the materials. The surface tension range for blood and body fluids (excluding saliva) is approximately 0.042 to 0.060 N/m (7) . To help simulate the wetting characteristics of blood and body fluids, the surface tension of the Phi-X174 Bacteriophage challenge suspension is adjusted to approximate the lower end of this surface tension range. This is accomplished by adding surfactant to the Phi-X174 Bacteriophage nutrient broth. The resulting surface tension of the Phi-X174 Bacteriophage challenge suspension is approximately 0.042 ± 0.002 N/m.

5.7 Testing prior to degradation by physical, chemical, and thermal stresses which could negatively impact the performance of the protective material, could lead to a false sense of security. Additional tests should be considered that assess the impact of storage conditions and shelf life on disposable products and the impact of laundering and sterilization on reusable products. The integrity of the protective barrier may also be compromised during use by such effects as flexing and abrasion (8). Prewetting agents, such as alcohol, and contaminating agents, such as perspiration, may also compromise the integrity of the protective barrier. If these conditions are of concern, the performance of protective clothing materials should be evaluated for Phi-X174 Bacteriophage penetration following an appropriate preconditioning technique representative of the expected conditions of use.

5.8 This test method involves a sensitive assay procedure for determining protective clothing material resistance to penetration by a surrogate microbe. Because of the length of time required to complete this method, it may not be suitable for use as a material or protective clothing quality control or quality assurance procedure.

5.9 If this procedure is used for quality control or to support broad product claims concerning the viral resistant properties of materials used in protective clothing, proper statistical design and analysis of larger data sets than those specified in this test method should be performed.9 Examples of acceptable sampling plans can be found in MIL-STD-105, ANSI/ASQC Z1.4, and ISO 2859-1.

5.10 This test method requires a working knowledge of basic microbiological techniques (9) .

Область применения

1.1 This test method is used to measure the resistance of materials used in protective clothing to penetration by blood-borne pathogens using a surrogate microbe under conditions of continuous liquid contact. Protective clothing material pass/fail determinations are based on the detection of viral penetration.

1.1.1 This test method is not always effective in testing protective clothing materials having thick, inner liners which readily absorb the liquid assay fluid.

1.2 This test method does not apply to all forms or conditions of blood-borne pathogen exposure. Users of the test method should review modes for worker/clothing exposure and assess the appropriateness of this test method for their specific applications.

1.3 This test method has been specifically defined for modeling the viral penetration of Hepatitis (B and C) and Human Immunodeficiency Viruses transmitted in blood and other potentially infectious body fluids. Inferences for protection from other pathogens must be assessed on a case-by-case basis.

1.4 This test method addresses only the performance of materials or certain material constructions (for example, seams) used in protective clothing and determined to be viral resistant. This test method does not address the design, overall construction and components, or interfaces of garments or other factors which may affect the overall protection offered by the protective clothing.

1.5 The values stated in SI units or in other units shall be regarded separately as standard. The values stated in each system must be used independently of the other, without combining values in any way.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
blood; blood-borne pathogens; body fluids; Phi-X174 Bacteriophage; protective clothing; viral penetration