(812) 309-78-59
(495) 223-46-76
ASTM F1895-10a
Practice for Submersion of a Membrane Switch
2 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
31.220.20 Switches / Переключатели
Сборник (ASTM):
10.04 Electronics; Declarable Substances in Materials; 3D Imaging Systems; Additive Manufacturing Technologies / Электроника; Декларируемые вещества в материалах; Системы 3D-визуализации; Аддитивные технологии производства
Тематика:
Electronics
Описание
Значение и использование

The presence of water inside a membrane switch can affect its mechanical operation or electrical functionality, or both. Electrical failure can result as short circuits due to silver migration or exceeding the specified resistance due to oxidation.

This test method establishes a procedure to verify the ability of a membrane switch to resist the entry of liquid in itself or a finished product, or both. It is useful in identifying design deficiencies.

Submersion testing may be destructive, therefore any samples tested should be considered unfit for future use.

Область применения

1.1 This test method establishes procedures for the submerging of a membrane switch to verify resistance to ingress of a specified liquid.

1.2 This test method can also be used to verify the ability of a membrane switch or graphics layer to act as a liquid seal for a finished product.

1.3 Additional test methods or practices can be incorporated to investigate specific results or capabilities.

1.4 This test method is a modification of National Electrical Manufacturers Assoc. (NEMA) Publication 250-1991 Section 6.10, which is a test for submersion of a finished product housing.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
immersion; membrane switch; submersion; water immersion; Immersion; Ingress resistance; Membrane switches; Resistance; Submersion; Water immersion testing