ASTM F2848-10
Standard Specification for Medical-Grade Ultra-High Molecular Weight Polyethylene Yarns
4 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
81.12 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
83.080.20 Thermoplastic materials / Термопластические материалы11.040.30 Surgical. Including surgical dressings, sutures, etc. / Хирургические инструменты и материалы. Включая перевязочные, шовные и другие материалы
Сборник (ASTM):
13.02 Medical and Surgical Materials and Devices (II): F2502–Latest; Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment / Медицинские и хирургические материалы и приборы (II): F2502-Latest; Скорая медицинская помощь; Поиск и Спасение; Оборудование для анестезии и искусственного дыхания
Тематика:
Medical Devices & Implants
Описание
Реферат

This specification describes the required properties and the procedures to be followed for testing ultra-high molecular weight polyethylene (UHMWPE) yarns intended for use in medical devices or components of medical devices, such as sutures and ligament fixations. UHMWPE filament and yarn requirements cover compositional requirements, physical requirements, mechanical requirements, and biocompatibility requirements. Residual production liquids shall be determined by gas chromatography or other suitable, validated analytical methods for the specific materials used to produce the yarn.

Область применения

1.1 This specification covers ultra-high molecular weight polyethylene (UHMWPE) yarns intended for use in medical devices or components of medical devices, such as sutures and ligament fixations.

1.2 This standard is intended to describe the required properties and the procedures to be followed for testing UHMWPE yarns as raw materials for medical devices. This specification does not purport to address the testing that is needed for medical devices or components of medical devices that are fabricated from the raw materials specified herein.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 The following precautionary caveat pertains only to the test method portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
fiber; high-modulus polyethylene (HMPE); high-performance polyethylene (HPPE); medical; surgical implants; ultra-high molecular weight polyethylene (UHMW-PE, UHMWPE); yarn