(812) 309-78-59
(495) 223-46-76
ASTM F2878-10
Standard Test Method for Protective Clothing Material Resistance to Hypodermic Needle Puncture
5 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
93.60 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.340.10 Protective. Including flameproof clothing / Защитная одежда. Включая огнестойкую одежду, индивидуальные плавсредства (спасательные жилеты)
Сборник (ASTM):
11.03 Occupational Health and Safety; Protective Clothing / Безопасность и охрана труда; Защитная спецодежда
Тематика:
Industrial Hygiene & Safety
Описание
Значение и использование

This test method evaluates puncture resistance of protective clothing materials which may include: plastics or elastomeric films, coated fabrics, flexible materials, laminates, leathers or textile materials.

This test method uses hypodermic needles with specified dimensions as puncture probes.

This test method evaluates puncture resistance of protective clothing materials, perpendicular to the materials surface and with no supporting structure under/behind the material specimen.

Evaluation of puncture resistance for snag-type puncture should be performed in accordance with Test Method D2582.

Evaluation of puncture resistance for non-cutting puncture should be performed in accordance with Test Method F1342.

Реферат

This test method is used for determining the force required to cause a hypodermic needle to penetrate through protective clothing material. It defines three common hypodermic needles - 21-, 25-, 28- gauge needles - to evaluate puncture resistance of protective clothing. This test method does not attempt to simulate all use conditions. A number of variables which impact puncture resistance, such as stiffness of backing materials, presence of lubricants, and tension on the specimen, are not addressed by this test method.

Область применения

1.1 This test method is used to determine the force required to cause a sharp-edged puncture probe (hypodermic needle) to penetrate through protective clothing material. The standard describes three test probes that may be used: 21-, 25-, or 28-gauge needles.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
hypodermic; needle; needle resistance; needlestick; prick; protective clothing materials; puncture; puncture resistance; stick