(812) 309-78-59
(495) 223-46-76
ASTM F609-05(2013)
Standard Test Method for Using a Horizontal Pull Slipmeter (HPS) (Withdrawn 2022)
3 стр.
Отменен
Электронный (pdf)Печатное издание
87.36 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
61.060 Footwear. Including shoelaces / Обувь. Включая шнурки
Сборник (ASTM):
15.07 Sports Equipment, Playing Surfaces and Facilities; Pedestrian/Walkway Safety and Footwear; Amusement Rides and Devices; Snow Skiing / Спортивное оборудование, игровые площадки и приспособления; Пешеходная безопасность; Обувная промышленность; Развлекательные аттракционы и механизмы; Лыжный спорт
Тематика:
Consumer Products
Описание
Причина отменыThis test method covers measurement of the slip index of footwear sole, heel, or related materials on dry walkway surfaces in the laboratory and in the field.

Formerly under the jurisdiction of Committee F13 on Pedestrian/Walkway Safety and Footwear, this test method was withdrawn in January 2022 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

4.1 The Horizontal Pull Slipmeter3 is a laboratory and field instrument designed to provide information about the slip index characteristics between walkway surfaces and a test foot material under dry conditions only. The HPS can not be used on wet surfaces. Slip index can be affected by surface roughness, presence of water, contaminants such as grease and other foreign materials, and floor surface wear over time. Slip index, as determined by the HPS, most likely will not give useful information for evaluating liquid contaminated surfaces, and therefore, will not provide an effective assessment of a potential slipping hazard on a walkway surface under these conditions.

4.2 The value reported by the Horizontal Pull Slipmeter is called the slip index. Slip index is ten times the static coefficient of friction. For example, a static coefficient of friction of 0.4 is displayed by a slip index of 4.0 when measured by the Horizontal Pull Slipmeter.

4.3 The HPS can be used on inclined surfaces. No adjustment for slope is needed for measurements in the direction perpendicular to the slope and when averaging four measurements at one location taken according to step 10.14.

Область применения

1.1 This test method covers measurement of the slip index of footwear sole, heel, or related materials on dry walkway surfaces in the laboratory and in the field.

1.2 The dimensional values used in the test method are given in units of inches, pounds, or degrees Fahrenheit. Alternative equivalent values are in parentheses and are for informational purposes only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
shoe heel; shoe soling; slip index; static coefficient of friction