ASTM G184-06
Standard Practice for Evaluating and Qualifying Oil Field and Refinery Corrosion Inhibitors Using Rotating Cage
6 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
93.60 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
75.200 Petroleum. Including petroleum and natural gas storage devices, distribution systems, pipelines, petrol stations, dispensing devices, etc. / Оборудование для переработки нефтяных продуктов и
Сборник (ASTM):
03.02 Corrosion of Metals; Wear and Erosion / Коррозия металлов; Износ и разрушение (эрозия) металлов
Тематика:
Corrosion & Wear
Описание
Значение и использование

Selection of corrosion inhibitor for oil field and refinery applications involves qualification of corrosion inhibitors in the laboratory (see Guide G 170). Field conditions should be simulated in the laboratory in a fast and cost-effective manner (1).3

Oil field corrosion inhibitors should provide protection over a range of flow conditions from stagnant to that found during typical production conditions. Not all inhibitors are equally effective over this range of conditions so it is important for a proper evaluation of inhibitors to test the inhibitors using a range of flow conditions.

The RC test system is relatively inexpensive and uses simple flat specimens that allow replicates to be run with each setup. (2-13).

In this practice, a general procedure is presented to obtain reproducible results using RC to simulate the effects of different types of coupon materials, inhibitor concentrations, oil, gas and brine compositions, temperature, pressure, and flow. Oil field fluids may often contain sand; however, this practice does not cover erosive effects that occur when sand is present.

Область применения

1.1 This practice covers a generally accepted procedure to use the rotating cage (RC) for evaluating corrosion inhibitors for oil field and refinery applications.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
corrosion inhibitor; high-pressure; high-temperature; laboratory evaluation; mass loss; oil-field inhibitors; RC; refinery inhibitors; rotating cage