(812) 309-78-59
(495) 223-46-76
ÖNORM EN 16171:2017-01
Sludge, treated biowaste and soil - Determination of elements using inductively coupled plasma mass spectrometry (ICP-MS)
Действует
Печатная копияПечатное издание
175.43 € (включая НДС 20%)
Разработчик:
Зарубежные/ON
ICS:
13.030.01 Wastes in general / Отходы в целом13.080.10 Chemical characteristics of soils / Химические характеристики грунтов
Описание
This European Standard specifies a method for the determination of the following elements in aqua regia or nitric acid digests of sludge, treated biowaste and soil:
Aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), bismuth (Bi), boron (B), cadmium (Cd), calcium (Ca), cerium (Ce), cesium (Cs), chromium (Cr), cobalt (Co), copper (Cu), dysprosium (Dy), erbium (Er), europium (Eu), gadolinium (Gd), gallium (Ga), germanium (Ge), gold (Au), hafnium (Hf), holmium (Ho), indium (In), iridium (Ir), iron (Fe), lanthanum (La), lead (Pb), lithium (Li), lutetium (Lu), magnesium (Mg), manganese (Mn), mercury (Hg), molybdenum (Mo), neodymium (Nd), nickel (Ni), palladium (Pd), phosphorus (P), platinum (Pt), potassium (K), praseodymium (Pr), rhenium (Re), rhodium (Rh), rubidium (Rb), ruthenium (Ru), samarium (Sm), scandium (Sc), selenium (Se), silicon (Si), silver (Ag), sodium (Na), strontium (Sr), sulfur (S), tellurium (Te), terbium (Tb), thallium (Tl), thorium (Th), thulium (Tm), tin (Sn), titanium (Ti), tungsten (W), uranium (U), vanadium (V), ytterbium (Yb), yttrium (Y), zinc (Zn), and zirconium (Zr).
The working range depends on the matrix and the interferences encountered.
The method detection limit of the method is between 0,1 mg/kg dry matter and 2,0 mg/kg dry matter for most elements. The limit of detection will be higher in cases where the determination is likely to be interfered (see Clause 4) or in case of memory effects (see e.g. EN ISO 17294-1:2006, 8.3).
The method has been validated for the elements given in Table A.1 (sludge), Table A.2 (compost) and Table A.3 (soil). The method is applicable for the other elements listed above, provided the user has verified the applicability.
Diese Europäische Norm legt ein Verfahren fest, nach dem in Aufschlusslösungen von Schlamm, behandeltem Bioabfall und Boden nach Königswasser- und Salpetersäureaufschluss die folgenden Elemente bestimmt werden:
Aluminium (Al), Antimon (Sb), Arsen (As), Barium (Ba), Beryllium (Be), Bismut (Bi), Blei (Pb), Bor (B), Cadmium (Cd), Caesium (Cs), Calcium (Ca), Cer (Ce), Chrom (Cr), Cobalt (Co), Dysprosium (Dy), Eisen (Fe), Erbium (Er), Europium (Eu), Gadolinium (Gd), Gallium (Ga), Germanium (Ge), Gold (Au), Hafnium (Hf), Holmium (Ho), Indium (In), Iridium (Ir), Kalium (K), Kupfer (Cu), Lanthan (La), Lithium (Li), Lutetium (Lu), Magnesium (Mg), Mangan (Mn), Molybdän (Mo), Natrium (Na), Neodym (Nd), Nickel (Ni), Palladium (Pd), Phosphor (P), Platin (Pt), Praseodym (Pr), Quecksilber (Hg), Rhenium (Re), Rhodium (Rh), Rubidium (Rb), Ruthenium (Ru), Samarium (Sm), Scandium (Sc), Schwefel (S), Selen (Se), Silber (Ag), Silicium (Si), Strontium (Sr), Tellur (Te), Terbium (Tb), Thallium (Tl), Thorium (Th), Thulium (Tm), Titan (Ti), Uran (U), Vanadium (V), Wolfram (W), Ytterbium (Yb), Yttrium (Y), Zink (Zn), Zinn (Sn) und Zirconium (Zr).
Der Arbeitsbereich hängt von der Matrix und den zu erwartenden Interferenzen ab.
Die Nachweisgrenze des Verfahrens für die meisten Elemente liegt zwischen 0,1 mg/kg Trockenmasse und 2,0 mg/kg Trockenmasse. Die Nachweisgrenze wird höher ausfallen, wenn bei der Bestimmung Interferenzen möglich sind (siehe Abschnitt 4), oder Memoryeffekte (Verschleppungseffekte) auftreten (siehe z. B. EN ISO 17294-1:2006, 8.3).
Das Verfahren wurde für die Elemente, die in Tabelle A.1 (Schlamm), Tabelle A.2 (Kompost) und Tabelle A.3 (Boden) aufgeführt sind, validiert. Das Verfahren ist für andere als oben aufgeführte Elemente anwendbar, sofern der Anwender die Anwendbarkeit überprüft hat.
Ключевые слова:
Boden (Erde), Pflanzenstandort, Schlamm, behandelter Bioabfall, Bioabfall, Bestimmung, Spurenelement, Massenspektrometrie, induktiv gekoppeltem Plasma, ICP-MS, Salpetersäureaufschluss, Chemikalien, Reagenzien, Geräte, Durchführung, Berechnung, Ergebnisangabe, Analysenbericht, Strontium, Bismut, Klärschlamm, Blei, Magnesium, Aluminium, Calcium, Lithium, chemisches Element, Boden, Bodenuntersuchung, Bor, Cadmium, Caesium, Arsen, Königswasser, Ruthenium, ICP, Hafnium, Gold, Germanium, Chrom, Gallium, Mangan, Eisen, Gehaltsbestimmung, Iridium, Kalium, Kobalt, Kompost, Barium, Indium, Antimon, Plasma, Salpetersäure, Zirkonium, Natrium, Palladium, Wolfram, Thallium, Nickel, Phosphor, Probenahme, Prüfung, Prüfverfahren, Quecksilber, Rhenium, Rhodium, Rubidium, Beryllium, Schwefel, Platin, Molybdaen, Selen, Silber, Tellur, Thorium, Yttrium, Kupfer, Silicium, Zinn, Titan, Wasserwesen, Uran, Vanadium