ÖNORM EN ISO 11691:2010-01
Acoustics - Measurement of insertion loss of ducted silencers without flow - Laboratory survey method (ISO 11691:1995)
Заменен
Печатная копияПечатное издание
129.89 € (включая НДС 20%)
Разработчик:
Зарубежные/ON
ICS:
91.120.20 Acoustics in building. Sound insulation / Акустика в зданиях. Звукоизоляция91.140.30 Ventilation. Including ventilation ducts / Вентиляционные системы и системы кондиционирования воздуха. Включая вентиляционные каналы
Описание
This International Standard specifies a laboratory substitution
method to determine the insertion loss without flow of ducted, mainly absorbent, circular and rectangular silencers, as well as other duct elements for use in ventilating and air-conditioning systems.
NOTE 1 Laboratory measurement procedures for ducted silencers with superimposed flow are described in IS0 7235. This International Standard is applicable to silencers where the design velocity does not exceed 15 m/s. As the method does not include self-generated flow
noise, this International Standard is not suitable for tests on silencers where this type of noise is of great importance for the evaluation of the silencer performance. The insertion loss determined according to this International Standard in a laboratory will not necessarily be the same as the insertion loss that will be obtained in an installation in the field. Different sound and flow
fields in the duct will yield different results. As this International Standard requires regular test ducts, the results may include some flanking transmission via structural vibrations in the duct walls, that sets an upper limit to the insertion loss that can be determined.
NOTE 2 IS0 7235 gives methods for determining this limit. This International Standard is intended to be used for circular silencers with diameters of 80 mm to 2 000 mm or rectangular silencers with crosssectional areas within the same range.
Diese Norm beschreibt ein Substitutionsverfahren zur Bestimmung des Einfügungsdämpfungs-Maßes von Kanalschalldämpfern ohne Strömung sowie anderen Kanalelementen zum Einsatz in raumlufttechnischen Anlagen. Die Messung erfolgt unter Laborbedingungen an runden Schalldämpfern mit Durchmessern von 80 mm bis 2000 mm und an rechteckigen Schalldämpfern mit Querschnittsmaßen derselben Größenordnung.
Ключевые слова:
Akustik, Messung, Einfügungsdämpfung, Einfügungsdämpfungmaß, Schalldämpfer, Kanal, Strömung, Laborverfahren, Genauigkeitsklasse, Begriffe, Terminologie, Prüfeinrichtung, Abbildung, Schallquelle, Prüfverfahren, Messbericht, Ergebnisbericht