Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors (Withdrawn 2011)
9 стр.
Заменен
Электронный (pdf)Печатное издание
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
93.080.30 Road. Including road traffic warning and control systems, devices and installations (speed controls, traffic signal installations, vehicle loop detectors, pavement markers, manholes, etc.) / Дорожное оборудование и установки. Включая технические средства и установки для регулирования дорожного движения (ограничители скорости, сигнальные установки для регулирования движения, указатели объезда, элементы разметки проезжей части автодорог, смотровые колодцы и т.д.)
Сборник (ASTM):
12.01 Nuclear Energy (I) / Ядерная энергия (I)
Тематика:
Nuclear Technology
Описание
Причина отмены

This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors.

Formerly under the jurisdiction of Committee C26 on Nuclear Fuel Cycle, this guide was withdrawn in January 2011 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

SNM monitors are an effective means to search pedestrians for concealed SNM. Maintaining monitor effectiveness rests on appropriate calibration and adjustment being part of a continuing maintenance program.

The significance of this guide for monitor users who must detect SNM is to describe calibration and adjustment procedures for the purpose.

The significance of this guide for monitor manufacturers is to describe calibration procedures, particularly for detecting forms of SNM that may not be readily available to them.

Область применения

1.1 This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors.

1.2 Automatic pedestrian SNM Monitors and their application are described in Guide C 1112, which suggests that the monitors be calibrated and tested when installed and that, thereafter, the calibration should be checked and the monitor tested with SNM at three-month intervals.

1.3 Dependable operation of SNM monitors rests, in part, on an effective program to test, calibrate, and maintain them. The procedures and methods described in this guide may help both to achieve dependable operation and obtain timely warning of misoperation.

1.4 This guide can be used in conjunction with other ASTM standards. illustrates the relationship between calibration and other procedures described in standard guides, and it also shows how the guides relate to an SNM monitor user. The guides below the user in the figure deal with routine procedures for operational monitors. Note that Guide C 993 is an in-plant performance evaluation that is used to verify acceptable detection of SNM after a monitor is calibrated. The guides shown above the user in give information on applying SNM monitors (C 1112) and on evaluating SNM monitors (C 1169) to provide comparative information on monitor performance.

Ключевые слова:
gamma radiation; material control and accountability; neutron radiation; nuclear materials management; radiation detectors; radiation monitors; safeguards; security