(812) 309-78-59
(495) 223-46-76
ASTM E34-11e1
Standard Test Methods for Chemical Analysis of Aluminum and Aluminum-Base Alloys (Withdrawn 2017)
29 стр.
Отменен
Электронный (pdf)Печатное издание
138.84 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
77.040.30 Chemical analysis of metals / Химический анализ металлов
Сборник (ASTM):
03.05 Analytical Chemistry for Metals, Ores, and Related Materials / Аналитическая химия для металлов, руд и сопутствующих материалов: с E32 и далее
Тематика:
Analytical Chemistry
Описание
Причина отменыThese test methods covered the chemical analysis of aluminum and aluminum-base alloys.

Formerly under the jurisdiction of Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials, these test methods were withdrawn in September 2017 and replaced by Test Method E3061 on the Analysis of Aluminum and Aluminum Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance Based Method)1

Значение и использование

These test methods for the chemical analysis of metals and alloys are primarily intended to test such materials for compliance with compositional specifications. It is assumed that all who use these test methods will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.


Note—Shaded areas are suitable for sampling.

FIG. 1 Type A and Type B Disks

Область применения

1.1 These test methods cover the chemical analysis of aluminum and aluminum-base alloys having compositions within the following limits:

Beryllium, ppm0.3 to 100
Bismuth, %0.02 to 1.0
Boron, %0.005 to 0.060
Cadmium, %0.001 to 0.50
Chromium, %0.01 to 1.0
Copper, %0.01 to 20.0
Gallium, %0.001 to 0.05
Iron, %0.01 to 3.0
Lead, %0.01 to 1.0
Lithium, %0.001 to 4.0
Magnesium, %0.002 to 12.0
Manganese, %0.005 to 2.0
Nickel, %0.01 to 4.0
Silicon, %0.05 to 20.0
Tin, %0.03 to 1.0
Titanium, %0.002 to 0.30
Vanadium, %0.002 to 0.16
Zinc, %0.003 to 12.0
Zirconium, %0.01 to 0.30

1.2 The analytical procedures appear in the following sections:

Procedure Sections
Beryllium:
Beryllium by Argon Plasma Optical Emission
Spectroscopy
283 to 292
Beryllium by the Morin (Fluorometric) Test
Method
1e
Bismuth:
Bismuth by the Thiourea (Photometric) Method1a
Bismuth and Lead by the Atomic Absorption
Test Method
188 to 198
Boron:
Boron by the Carmine (Photometric) Test Method1e
Cadmium:
Cadmium by the Atomic Absorption Test Method167 to 177
Chromium:
Chromium by the Diphenylcarbazide (Photometric)
Test Method
1e
Chromium by the Persulfate Oxidation (Titrimetric)
Test Method
1b
Chromium by the Atomic Absorption Test Method199 to 209
Copper:
Copper and Lead by the Electrolytic (Gravimetric)
Test Method
1c
Copper and Zinc by the Atomic Absorption
Spectometry Test Method
210 to 220
Copper by the Electrolytic (Gravimetric) Test Method303 to 311
Copper by the Neocuproine (Photometric)
Test Method
1a
Gallium:
Gallium by the Ion Exchange-Atomic Absorption
Test Method
312 to 323
Iron:
Iron by the 1,10-Phenanthroline (Photometric) Method 73 to 81
Iron and Manganese by the Atomic Absorption
Spectometry Method
221 to 231
Lead:
Copper and Lead by the Electrolytic (Gravimetric)
Test Method
1 c
Bismuth and Lead by the Atomic Absorption
Spectrometry Test Method
188 to 198
Lithium:
Lithium by the Atomic Absorption Test Method324 to 334
Magnesium:
Magnesium by the Pyrophosphate (Gravimetric)
Method
1 b
Magnesium by the Ethylenediamine Tetraacetate
(Titrimetric) Test Method
1 e
Magnesium by the Atomic Absorption Spectrometry
Test Method
232 to 242
Manganese:
Iron and Manganese by the Atomic Absorption
Spectrometry Test Method
221 to 231
Manganese by the Periodate (Photometric)
Test Method
293 to 302
Nickel:
Nickel by the Dimethylglyoxime (Photometric)
Test Method
1a
Nickel by the Dimethylglyoxime (Gravimetric)
Test Method
1b
Nickel by the Atomic Absorption Spectrometry
Test Method
243 to 253
Silicon:
Silicon by the Molybdisilicic Acid (Photometric)
Test Method
1 e
Silicon by the Sodium Hydroxide-Perchloric Acid
(Gravimetric) Method
1 e
Tin:
Tin by the Iodate (Titrimetric) Test Method1 e
Titanium:
Titanium by the Chromotropic Acid (Photometric)
Test Method
141 to 150
Titanium by the Diantipyrylmethane Photometric
Test Method
254 to 263
Vanadium:
Vanadium by an Extraction-Photometric Test Method
using N-Benzoyl-N-Phenylhydroxylamine
264 to 273
Zinc:
Zinc by the Ammonium Mercuric Thiocyanate or the
Zinc Oxide (Gravimetric) Test Method
1b
Zinc by the Ethylenediamine Tetraacetate
(Titrimetric) Test Method
1d
Copper and Zinc by the Atomic Absorption
Spectrometry Test Method
210 to 220
Zinc by the Ion Exchange-EDTA Titrimetric
Test Method
274 to 282
Zirconium:
Zirconium by the Arsenazo III (Photometric) Method178 to 187

1.3 The values stated in SI units are to be regarded as the standard.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given throughout these test methods.