(812) 309-78-59
(495) 223-46-76
IEC 60695-2-11:2014 ed2.0
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
30 стр.
Заменен
Электронный (pdf)Печатная копия
131.04 CHF (включая НДС 20%)
Разработчик:
Зарубежные/IEC
ICS:
13.220.40 Ignitability and burning behaviour of materials and products / Воспламеняемость, поведение материалов и продуктов при горении29.020 Electrical. Including voltages, general electrical terminology, electrical documentation, electrical tables, safety, fire hazard testing, etc. / Электротехника в целом. Включая напряжение, общую терминологию, электротехническую документацию, электрические таблицы, безопасность, испытания на пожароопасность и т.д.
Описание
IEC 60695-2-11:2014 is available as IEC 60695-2-11:2014 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60695-2-11:2014 specifies a test method on an end product. It is intended to simulate the effects of thermal stresses produced by an electrically heated source to represent a fire hazard. This test method is used to check that, under defined test conditions, an end product exposed to an electrically heated source has either a limited ability to ignite or, if it ignites, a limited ability to propagate flame. However, the fire hazard analysis, the flammability aspects and the flame spreading to otherproducts are not covered by the present standard. This second edition of IEC 60695-2-11 cancels and replaces the first edition of IEC 60695-2-11 published in 2000. It constitutes a technical revision. The main changes with respect to the previous edition are:
- the Introduction has been added to provide background and how it relates to the Scope,
- the Scope has been modified for greater clarity and reference to basic safety publications,
- numerous terms and definitions relevant to this Standard have been added to Clause 3,
- the application of "small parts" and "insignificant mass" have been introduced and clarified,
- the different types of specimens, how to specify them, and limitations of the test method have been further clarified in Clause 4,
- clarified in Clause 5 the distance to specified layer when unknown,
- the information from Clause 6 has been moved into the test procedure in Clause 8,
- the conditioning of the specified layer and the laboratory ambient test conditions were clarified in Clause 7,
- measurement of the maximum flame height was removed from Clause 9,
- the reference to this test as "GWEPT" was introduced along with an applicable title change and
- Annex A has been revised to reflect current practice by prominent product committees.
Key words: Glowing/hot-wire, Glow wire, Flammability, Fire hazard
This publication is to be read in conjunction with IEC 60695-2-10:2013.