(812) 309-78-59
(495) 223-46-76
ASTM D1016-05(2015)
Standard Test Method for Purity of Hydrocarbons from Freezing Points (Withdrawn 2019)
13 стр.
Отменен
Печатное изданиеЭлектронный (pdf)
104.52 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
71.080.01 Organic chemicals in general / Органические химические вещества в целом
Сборник (ASTM):
05.01 Petroleum Products, Liquid Fuels, and Lubricants (I): C1234–D3709 / Нефтепродукты, жидкое топливо и смазочные материалы (I): C1234–D3709
Тематика:
Petroleum
Описание
Причина отменыThis test method covers the sampling and determination of purity of essentially pure compounds for which the freezing points for zero impurity and cryoscopic constants are given.

Formerly under the jurisdiction of Committee D02 on Petroleum Products, Liquid Fuels, and Lubricants, this test method was withdrawn in December 2019 for the following reasons: (1) D1015 was developed, along with D1016, in the 1940s for the purpose of determination of purity of hydrocarbons using freezing point measurements. This method of testing hydrocarbon purity has been replaced by more precise instrument techniques such as gas chromatography in the industry. (2) The precision statements (repeatability and reproducibility) do not conform to current ASTM requirements and the precision of the method was not obtained in accordance with RR: D02-1007 or ASTM D6300. This standard, together with its companion method D1015, is being withdrawn with no replacement because it is no longer relevant as it is not used by the industry.

Значение и использование

4.1 The experimental procedures and physical constants provided by this test method, when used in conjunction with Test Method D1015, allow the determination of the purity of the material under test. A knowledge of the purity of these hydrocarbons is often needed to help control their manufacture and to determine their suitability for use as reagent chemicals or for conversion to other chemical intermediates or finished products.

Область применения

1.1 This test method covers the sampling and determination of purity of essentially pure compounds for which the freezing points for zero impurity and cryoscopic constants are given.2 The compounds to which the test method is applicable are: (Warning—Extremely flammable liquids and liquefied gases.)

n-butane

1,3-butadiene

isobutane

isoprene(2-methyl-1,3-butadiene)

n-pentane

benzene

isopentane

toluene (methylbenzene)

n-hexane

ethylbenzene

n-heptane

o-xylene (1,2-dimethylbenzene)

n-octane

m-xylene (1,3-dimethylbenzene)

2,2,4-trimethylpentane

p-xylene (1,4-dimethylbenzene)

methylcyclohexane

styrene (ethenylbenzene)

isobutene

 

1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections 1, 6, 8, and 10 – 26.

Note 1: This test method covers systems in which the impurities form with the major component a substantially ideal or sufficiently dilute solution, and also systems which deviate from the ideal laws, provided that, in the latter case, the lowering of the freezing point as a function of the concentration is known for each most probable impurity in the given substance.

Ключевые слова:
crystallization; freeze point; LPG; pure hydrocarbons; purity;