(812) 309-78-59
(495) 223-46-76
ASTM F1662-10
Standard Test Method for Verifying the Specified Dielectric Withstand Voltage and Determining the Dielectric Breakdown Voltage of a Membrane Switch
2 стр.
Заменен
Электронный (pdf)Печатное издание
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
29.120.40 Switches / Переключатели
Сборник (ASTM):
10.04 Electronics; Declarable Substances in Materials; 3D Imaging Systems; Additive Manufacturing Technologies / Электроника; Декларируемые вещества в материалах; Системы 3D-визуализации; Аддитивные технологии производства
Тематика:
Electronics
Описание
Значение и использование

Dielectric withstand voltage testing is useful for design verification, quality control of materials, and workmanship.

This test method is used to verify that the membrane switch can operate safely at its rated voltage, and withstand momentary overpotentials due to switching, surges and other similar electrical phenomena.

Specific areas of testing are, but not limited to:

Conductor/dielectric/conductor crossing point,

Close proximity of conductors, and

Any other conductive surface such as shielding or metal backing panel.

Dielectric withstand voltage testing may be destructive and units that have been tested should be considered unreliable for future use.

Testing using ac voltage may be useful for switches intended for control circuits powered by ac voltages.

Область применения

1.1 This test method covers the verification of a specified dielectric withstand voltage or dielectric breakdown voltage of a membrane switch.

Ключевые слова:
dielectric withstand voltage; dielectric breakdown voltage; membrane switch; Dielectric breakdown voltage; Dielectric withstand voltage; Electronic materials/applications; Insulation resistance; Membrane switches; Voltage; Withstand voltage