(812) 309-78-59
(495) 223-46-76
ASTM C1765-13
Standard Specification for Steel Fiber Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe
6 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
93.60 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
23.040.50 Pipes and fittings of other materials / Трубы и фитинги из других материалов
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Реферат

This specification establishes the requirements for steel fiber reinforced concrete pipe (SFRCP) of internal diameters 12-48 in., to be used in the conveyance of sewage, industrial wastes, and storm water as well as the construction of culverts. Pipe furnished under this specification shall be designated as Class I, II, III, IV, or V. The standard covers the basis of acceptance of the pipe design, design and manufacturing, materials and manufacture, proof of design testing, physical requirements, compression tests for determining th compressive strength of steel fiber concrete, dimensions and permissible variations, repairs, inspection and rejection, disposition of a rejected lot, certification, and product marking. Definitions of terms relating to concrete pipe are provided, including D-load, the load the pipe is required to support in the three-edge bearing test.

Область применения

1.1 This specification covers steel fiber reinforced concrete pipe (SFRCP) of internal diameters 12 - 48 in., intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts.

Note 1Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relation ship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Ключевые слова:
circular pipe; D load; sewer pipe; SFRCP; steel fibers; storm drains; three edge bearing strength