ASTM C950-81(1993)
Standard Practice for Repair of a Rigid Cellular Polyurethane Insulation System on Outdoor Service Vessels
2 стр.
Заменен
Электронный (pdf)Печатное издание
81.12 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
Сборник (ASTM):
04.06 Thermal Insulation; Building and Environmental Acoustics / Теплоизоляция; Внутренняя звукоизоляция зданий и звукоизоляция от внешней среды
Тематика:
Thermal Insulation
Описание
Область применения

1.1 This practice covers the repair of spray-applied polyurethane insulation on vessels normally operating at temperatures between -30 and + 107oC (-22 and + 225oF).

1.2 Caution-At temperatures below 0oC (32oF) the application of a spray "foam" directly onto the cold substrate may not be possible. The term "foam" applies to spray-applied polyurethane or polyisocyanurate (PUR or PIR) rigid cellular plastic only, and not to any other plastic insulation.

1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see 1.2 and 5.1.2.

Ключевые слова:
coating; outdoor service vessels; spray foam