ASTM C980-10
Standard Specification for Industrial Chimney Lining Brick
3 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
91.100.15 Mineral. Including earth, sands, clay, slates, stones, etc. / Минеральные материалы и изделия. Включая землю, песок, глину, шифер, камень, кирпич и т.д.
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Реферат

This specification covers solid kiln fired brick made from clay, shale, or mixtures thereof suitable for use in masonry construction in contact with the chemicals present in flue gases found in industrial chimneys. These brick are normally used with chemical-resistant mortars. Chimney lining bricks are classified according to types: Types I, II, and III. The following test methods shall be performed for the materials to meet the specified requirements: sulfuric acid boil test: compressive strength test; water absorption; sizes; warpage; and texture.

Область применения

1.1 This specification covers solid kiln fired brick made from clay, shale, or mixtures thereof suitable for use in masonry construction in contact with the chemicals present in flue gases found in industrial chimneys. These brick are normally used with chemical-resistant mortars.

1.2 The physical and chemical properties of chimney lining brick differ from supplier to supplier mainly because their composition is determined by the source of raw materials. Chimney lining brick, regardless of these differences, are considered to be of three types noted as follows:

1.2.1 Type IFor use where low absorption and high acid resistance are not major factors.

1.2.2 Type IIFor use where lower absorption and higher acid resistance are required.

1.2.3 Type IIIFor use where lowest absorption and highest acid resistance are required.

Note 1—Types I, II, and III may not differ significantly in their resistance to thermal shock, and selection of brick type should be based upon their absorption and acid-resistant service requirements.

1.3 Terminology related to industrial floor brick is found in Terminology C1232.

1.4 UnitsThe values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
absorption; acid resistance; acid solubility; ceramic; industrial chimney; masonry; physical properties; solid brick; Solubility--sulfuric acid; Sulfuric acid solubility; Acid resistance; Airflow resistance; Brick--specifications; Chemical-resistant brick--specifications; Chemical-resistant materials/products--specifications; Chimney lining materials--specifications; Clay products (structural)--insulating; Industrial buildings/developments--specifications; Liner/linings--specifications; Masonry chimneys; Masonry units--specifications; Petroleum products (oil shale); Shale