ASTM D2522-03(2008)e2
Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation (Withdrawn 2017)
3 стр.
Отменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
29.035.20 Plastics. Including adhesive tapes / Пластмассовые и резиновые изоляционные материалы. Включая клейкие ленты
Сборник (ASTM):
10.03 Electrical Insulating Liquids and Gases; Electrical Protective Equipment / Электроизоляционные (изолирующие) жидкости и газы; Электрозащитное оборудование
Тематика:
Electrical Insulating Materials
Описание
Причина отменыThis test method describes the determination of the total chloride content of polybutenes used for electrical insulation.

Formerly under the jurisdiction of Committee D27 on Electrical Insulating Liquids and Gases, this test method was withdrawn in July 2017 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

Chlorine is normally present in polybutenes in small amounts, usually below 50 ppm, as organically bound chlorine. Inorganic chloride is normally not present.

Note 1—The qualitative presence or absence of inorganic chloride may be tested by Test Method D 878.

Область применения

1.1 This test method describes the determination of the total chloride content of polybutenes used for electrical insulation.

1.2 WarningMercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPAs website (http://www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards information, see Section 8.

Ключевые слова:
chlorine; electrical; insulating; insulation; polybutenes; Chlorine content; Electrical insulating materials; Electrical insulating oils; Insulation; Polybutylene (PB)